The objective of the EPRI ESCP Dose Modeling Task Group is to model a loaded cask and calculate the dose, with subsequent comparison of the results between the participants and with the measurement results, which will be known only after the calculations.
The dose measurement on the cask was carried out on 22 September 2018, but the results are not known to the participants. This is to prevent the modelling from being influenced by the measured results. A US cask (Holtec International MPC-68 with Holtec International HI-STORM 100 overpack) loaded with 68 BWR fuel assemblies with burn-ups of around 20 to 40 GWd/tHM will be modelled. The dose rate is calculated based on the irradiation history and the cask loading plan.
Participants’ results will be compared in terms of deviations in results, modelling and implementation of the benchmark specifications. The calculation results will also be compared with the measured values to allow conclusions to be drawn about the accuracy of generalised prediction models. The results will be published in an EPRI report.